Jumat, 18 Februari 2011

LID REBREATHING

INTERFACE WITH BAG LID REBREATHING
- Provide O2 with a flow of 8-12 L / min with a concentration of 40-60%
- Design rebreathing face shield similar to a simple face shield, with the addition of O2 reservoir bag
-Air inspiration partly mixed with air expression, 1 / 3 part ekshalasi volume into the bag, 2 / 3 part ekshalasi volume through the holes on the side
ADVANTAGES:
Saving Oxygen ekshalasi of anatomic dead space
LOSSES:
- Flow rate is not fit to lead back to CO2 inhalation
- Patients are not free to eat, drink, or cough
DANGER:
- There was an aspiration if vomiting
- Emphysema subcutaneous tissue into the eye at high O2 flow
- Necrosis due to mounting face that is too tight lid
MAINTENANCE:
- Advance the patient is cleaned and dried every 2 hours
- Fume face replaced / cleaned every 8 hours
- If there is water in the bag, it must be emptied
How to Install
- Explain the procedure in patients
- Connect the hose O2 on humidifier with low flow
- The contents of O2 into the bag by closing the hole between the pouch with a lid
- Adjust straps so that the lid closes tightly and comfortably, if necessary, wear gauze pads in a depressed area
- Adjust the flow of O2 so that the bag will be filled in expiratory time and inspiration time nearly bud

Tidak ada komentar:

Posting Komentar